温馨提示:该页面为Windows软件,不支持手机用户安装使用
The GB28181 Automation Testing Tool is a crucial asset for testing security monitoring systems. It can perform independent tests on DVRs or surveillance cameras that support the GB281 protocol before they are connected to a service platform. The tool comes with detailed user instructions.
Enable Connection: Ensure that the connection is enabled.
SIP Server IP: Input the IP address of the computer running the automation testing tool.
Device Serial Number and Channel Number: Fill out the table with the device's serial number and channel number. For multi-channel devices, video channel numbers should increase sequentially.
Other Settings: Keep other settings default (the default registration password is 12345678).
Click "Confirm".
Enter Device IP Address: Input the IP address of the device to be tested.
Local IP: Choose the IP address of the computer running the automated testing tool, which should match the "SIP Server IP" in Figure 1.
Device Type: Select the device type as IPC, DVR, or NVR, depending on the device.
Domain Configuration: Keep the sipID and sip domain in the domain configuration set to default.
Recording Time Setting: Set the start and end time to specify the recording time range for review. Ensure that all video channels have recordings during this period, and the time format must be yyyy-MM-ddThh:mm:ss.
Click "Confirm" to save the settings.
Select Test Cases: Click to select or manually choose the relevant test cases.
Run: Click "Run" to start the test cases automatically.
Completion Notification: After the test cases complete, a pop-up notification will appear. You can also manually stop the test.
Test results will be displayed under the test case tree, with green indicating a pass and red indicating a failure.
Incompatible Functions: For devices with incompatible functions, cancel the relevant test cases. For example, for IPCs that do not support PTZ control, cancel the "PTZ Control" test case.
Testing Sequence: When testing, run the test cases first, then register the device with the testing tool. Specifically, start by clicking "Run" on the automated testing tool, and then change the heartbeat interval (to around 60 seconds) on the device's Web "GB28181" page and click "Confirm" to ensure the test proceeds normally. A failed "Registration" test case usually indicates this issue.
Interactive Operations: Some test cases require immediate user interaction to proceed normally:
Video Channel Arm/Disarm and Alarm: When prompted, manually enable the video block alarm on the first channel within 60 seconds.
Alarm Channel Arm/Disarm and Alarm: When prompted, manually enable the IO alarm on the first channel within 60 seconds.
PTZ Control: When prompted, respond "Yes" or "No" within 5 seconds based on whether the PTZ is functioning correctly.
Full Recording: When prompted, immediately choose "Yes" or "No" based on whether the full recording control is effective.
Video and Audio Codecs: The current national standard video supports H.264 codec, and audio supports G711.a codec with a sampling rate of 8K. If there are issues with video or audio, check the corresponding codec settings.
Capture Logs: Each time the tool runs, it automatically saves GB28181 messages and media interaction captures to the path cache\GB28181\Capture
under the automated testing tool's working directory.
The GB28181 Automation Testing Tool offers a comprehensive suite of features designed to streamline the testing process of GB28181-compatible devices:
User-Friendly Interface: An intuitive interface that simplifies the configuration and execution of test cases.
Real-Time Monitoring: Provides real-time feedback on test progress and results.
Customizable Test Cases: Allows users to create and customize test cases to fit specific device requirements.
Detailed Reports: Generates detailed reports that can be exported for further analysis.
Error Logs: Captures and logs errors for easier troubleshooting.
To begin using the tool, follow these simple steps:
Download and Install: Obtain the tool from the official source and install it on your computer.
Configuration: Configure the GB28181 settings as per the instructions provided.
Add Devices: Add the devices you wish to test by following the device addition process.
Run Tests: Select the desired test cases and run them.
Review Results: Review the results to ensure that your devices meet the required standards.
By following these steps, you can ensure that your GB28181 devices are functioning correctly and compliant with the standards.
安装快捷方式
修改或删除您的SD卡中的内容
拥有完全的网络访问权限
控制振动
查看网络连接
开机启动
防止手机休眠
在其他应用之上显示内容
录音
更改您的音频设置
拍摄照片和视频
连接WLAN网络和断开连接
查看WLAN连接
关闭其他应用
卸载快捷方式
让应用始终运行
修改系统设置
检索正在运行的应用
读取您的通讯录
与蓝牙设备配对
访问蓝牙设置
发送持久广播
写入/删除您的通讯录
使用指纹硬件
更改网络连接性
展开/收拢状态栏
查找设备上的帐号
写入/删除您的通讯录
读取同步设置
启用和停用同步
停用屏幕锁定
允许接收WLAN多播
添加或修改日历活动,并在所有者不知情的情况下向邀请对象发送电子邮件
读取日历活动和机密信息
关闭其他应用
请求安装文件包
连接WLAN网络和断开连接
拥有完全的网络访问权限
查看WLAN连接
查看网络连接
访问确切位置信息(以 GPS 和网络为依据)
访问大致位置信息(以网络为依据)
拍摄照片和视频
防止手机休眠
安装快捷方式
开机启动
发送持久广播
控制近距离通信
对正在运行的应用重新排序
读取您的SD卡中的内容